Peak runoff Q equals the runoff coefficient C times the rainfall intensity i (for a storm lasting the time of concentration) times the drainage area A. In SI: \(Q\,[\text{m}^3/\text{s}] = C\,i\,A/360\) with i in mm/h and A in ha. In US units: \(Q\,[\text{cfs}] = C\,i\,A\) with i in in/h and A in acres. Use it for catchments up to roughly 80 ha (200 ac).
Rational Method Formula in SI and US Units
The rational method dates to Mulvaney (1851) in Ireland and Kuichling (1889) in the US. Its logic is a steady-state water balance: if rain falls at a constant intensity \(i\) on an area \(A\) for long enough, the outflow rate approaches the inflow rate \(iA\), reduced by the fraction lost to infiltration and storage, which is \(1-C\).
| System | Q | i | A | Conversion k |
|---|---|---|---|---|
| US customary | cfs (ft³/s) | in/h | acres | 1.008 ≈ 1 |
| SI (hectares) | m³/s | mm/h | ha | 1/360 = 0.00278 |
| SI (km²) | m³/s | mm/h | km² | 1/3.6 = 0.278 |
| SI (litres) | L/s | mm/h | ha | 2.78 |
Assumptions and Limitations
- Rainfall is uniform in space and time over the whole catchment for a duration at least equal to tc. This is only reasonable for small areas.
- Peak flow happens when the whole catchment contributes, i.e. when storm duration equals tc.
- C is constant during the storm and the same for all return periods (corrected for large storms with a frequency factor).
- The return period of Q equals the return period of i. A 10-year intensity gives a 10-year peak.
- No significant storage (ponds, wetlands, floodplains) in the catchment.
The rational method gives only a peak, not a hydrograph or a runoff volume. It cannot size detention ponds on its own (the "modified rational method" extends it with a trapezoidal hydrograph for preliminary detention sizing).
Runoff Coefficient (C) Table
C is the most subjective input. It lumps infiltration, depression storage, evaporation and attenuation into one number, so use local design-manual values where they exist.
By land use (TxDOT Hydraulic Design Manual, Table 4-10)
| Land use / surface | C |
|---|---|
| Downtown business areas | 0.70–0.95 |
| Single-family residential | 0.30–0.50 |
| Apartment dwelling areas | 0.30–0.70 |
| Light industrial | 0.30–0.80 |
| Heavy industrial | 0.60–0.90 |
| Parks, cemeteries | 0.10–0.25 |
| Asphaltic streets | 0.85–0.95 |
| Concrete streets | 0.90–0.95 |
| Roofs | 0.75–0.95 |
Lawns and other surfaces (ASCE & WPCF 1969, as reproduced in Chow et al. 1988)
| Surface | Flat (≤ 2%) | Average (2–7%) | Steep (≥ 7%) |
|---|---|---|---|
| Lawns, sandy soil | 0.05–0.10 | 0.10–0.15 | 0.15–0.20 |
| Lawns, heavy (clay) soil | 0.13–0.17 | 0.18–0.22 | 0.25–0.35 |
Rural watersheds (TxDOT Table 4-11): C = Cr + Ci + Cv + Cs
| Component | Extreme | High | Normal | Low |
|---|---|---|---|---|
| Relief Cr | 0.28–0.35 | 0.20–0.28 | 0.14–0.20 | 0.08–0.14 |
| Soil infiltration Ci | 0.12–0.16 | 0.08–0.12 | 0.06–0.08 | 0.04–0.06 |
| Vegetal cover Cv | 0.12–0.16 | 0.08–0.12 | 0.06–0.08 | 0.04–0.06 |
| Surface storage Cs | 0.10–0.12 | 0.08–0.10 | 0.06–0.08 | 0.04–0.06 |
Composite C and frequency factor
Time of Concentration (tc) Formulas
The time of concentration is the travel time of runoff from the hydraulically most distant point to the outlet. It sets the design storm duration, so errors in tc go straight into i and Q. Empirical formulas differ a lot because they were built for different flow types.
Rainfall Intensity from IDF Curves
The intensity \(i\) is read from an intensity–duration–frequency (IDF) curve for the design return period, at a duration equal to tc. IDF relationships are often fitted as:
- United States: NOAA Atlas 14 through the Precipitation Frequency Data Server (PFDS). NOAA Atlas 15, which accounts for climate change, is in development; NOAA's schedule lists preliminary CONUS estimates no earlier than September 2026 and published estimates no earlier than September 2027.
- Elsewhere: national meteorological or hydrology departments publish IDF curves or equations; in data-scarce regions, IDF curves are derived from annual maximum rainfall series fitted with Gumbel or GEV distributions.
Worked Example 1 (SI): Small Urban Catchment
Given: a 12 ha catchment with 4 ha of roofs and paved surfaces (C = 0.90), 5 ha of lawns on heavy soil, flat (C = 0.20), and 3 ha of park (C = 0.15). Longest flow path L = 650 m with a fall of 9.75 m, mostly in a natural channel. Local 10-year IDF (illustrative): \(i = 1600/(t+12)^{0.75}\) mm/h.
- Composite C: \(C = (0.90\times4 + 0.20\times5 + 0.15\times3)/12 = 5.05/12 = 0.421\)
- Slope: \(S = 9.75/650 = 0.015\) m/m
- tc by Kirpich (k = 1): \(t_c = 0.0195 \times 650^{0.77} \times 0.015^{-0.385} = 14.4\) min (above the 10-minute minimum)
- Intensity: \(i = 1600/(14.4+12)^{0.75} = 137.4\) mm/h
- Peak flow: \(Q = 0.421 \times 137.4 \times 12 / 360 = 1.93\) m³/s (≈ 1,930 L/s)
This example is pre-loaded in the calculator. Switch the tc method to FAA to see the peak fall to about 1.02 m³/s, a reminder to choose the tc method that matches the actual flow path.
Worked Example 2 (US): 25-Year Design with Frequency Factor
Given: A = 25 acres, composite C = 0.55, tc = 18 min, and the 25-year IDF curve gives i = 4.2 in/h at 18 minutes. The governing manual uses Cf = 1.1 for 25-year storms.
- Check CfC ≤ 1: 1.1 × 0.55 = 0.605 ✓
- Peak flow: \(Q = C_f\,C\,i\,A = 0.605 \times 4.2 \times 25 = 63.5\) cfs (≈ 1.80 m³/s)
Rational Method Calculator
1 · Runoff coefficient (composite)
2 · Time of concentration
3 · Rainfall intensity
Q(t) = C·i(t)·A·min(1, t/tc). Shorter storms are more intense but only part of the catchment contributes; the peak is at t = tc.
Rational Method vs SCS Curve Number Method
| Aspect | Rational method | SCS-CN method |
|---|---|---|
| Output | Peak discharge Q | Runoff depth and volume |
| Rainfall input | Intensity for duration tc | Total storm depth |
| Catchment size | Small (≲ 80 ha / 200 ac) | Small to large (with routing) |
| Loss parameter | C (0–1) | CN (30–100) |
| Hydrograph | No (modified rational: approximate) | Yes, with a unit hydrograph |
| Typical use | Storm sewers, inlets, gutters, small culverts | Detention, floodplain studies, watershed models |
Try the SCS Curve Number Runoff Calculator for the volume side of the same problem.
Common Mistakes in Rational Method Calculations
Mixing units
Using mm/h with acres, or forgetting /360 with hectares. Write the units next to every number.
Wrong duration
Reading the 60-minute intensity when tc is 15 minutes can under-estimate Q by half or more.
One tc formula for every flow path
Split the path into sheet, shallow concentrated and channel flow, and add the times.
Ignoring the size limit
Applying the method to a 5 km² rural catchment ignores rainfall variability and storage.
Area-weighting tc or i
Only C is area-weighted. When combining sub-catchments downstream, use the longest tc to the design point and ΣCA.
Partial-area effect
A small paved area near the outlet with a short tc can produce a higher peak than the whole catchment. Check it.
Related Tools and Guides
Frequently Asked Questions
What is the rational method formula?
Q = C i A. In US units Q is in cfs, i in in/h and A in acres (the conversion factor 1.008 is taken as 1). In SI units Q (m³/s) = C i A / 360 with i in mm/h and A in hectares, or Q = 0.278 C i A with A in km². C is the dimensionless runoff coefficient.
What is the maximum drainage area for the rational method?
It is intended for small catchments. TxDOT limits it to about 200 acres (80 ha); many agencies use similar limits between roughly 20 and 200 acres. Larger areas violate the assumption of uniform rainfall over the whole catchment for a duration equal to the time of concentration, and storage effects become important.
Why is rainfall duration set equal to the time of concentration?
Peak flow occurs when the entire catchment contributes at once, which first happens after the time of concentration. Shorter storms are more intense but only part of the area contributes; longer storms cover the whole area but are less intense. For the rational method assumptions, duration = tc gives the maximum product i × contributing area.
What is a typical runoff coefficient for a residential area?
TxDOT gives C = 0.30–0.50 for single-family residential areas and 0.30–0.70 for apartment areas. Roofs are 0.75–0.95 and asphalt streets 0.85–0.95. Lawns range from about 0.05 on flat sandy soil to 0.35 on steep clay soil. Mixed catchments use an area-weighted composite C.
Can C be greater than 1?
No. C is the fraction of rainfall that becomes peak runoff. When a frequency factor is applied for 25- to 100-year storms (1.1 to 1.25), the product C × Cf should be capped at 1.0.
What is the difference between the rational method and the SCS curve number method?
The rational method gives a peak discharge for small catchments using rainfall intensity. The SCS curve number method gives runoff depth and volume from storm rainfall depth and needs a separate timing method for peaks. Use rational for storm drains and culverts on small sites; use SCS-CN or a unit hydrograph for volumes, detention and larger watersheds.
References
Texas Department of Transportation (TxDOT). Hydraulic Design Manual, Chapter 4, Section 11 (Time of Concentration) and Section 12 (Rational Method). txdot.gov
Chow, V. T., Maidment, D. R., & Mays, L. W. (1988). Applied Hydrology, Chapter 15. McGraw-Hill, New York.
ASCE & WPCF (1969). Design and Construction of Sanitary and Storm Sewers. ASCE Manual of Practice No. 37.
Kirpich, Z. P. (1940). Time of concentration of small agricultural watersheds. Civil Engineering, 10(6), 362.
Federal Aviation Administration (1970). Airport Drainage, Advisory Circular 150/5320-5B.
Kerby, W. S. (1959). Time of concentration for overland flow. Civil Engineering, 29(3), 174.
USDA Soil Conservation Service (1986). Urban Hydrology for Small Watersheds, TR-55.
NOAA National Water Center. NOAA Atlas 15 project status. water.noaa.gov/about/atlas15